# Hardware Inventory Complete hardware specifications for all homelab equipment. ## Servers ### PVE (10.10.10.120) - Primary Proxmox Server #### CPU - **Model**: AMD Ryzen Threadripper PRO 3975WX - **Cores**: 32 cores / 64 threads - **Base Clock**: 3.5 GHz - **Boost Clock**: 4.2 GHz - **TDP**: 280W - **Architecture**: Zen 2 (7nm) - **Socket**: sTRX4 - **Features**: ECC support, PCIe 4.0 #### RAM - **Capacity**: 128 GB - **Type**: DDR4 ECC Registered - **Speed**: Unknown (needs investigation) - **Channels**: 8-channel (quad-channel per socket) - **Idle Power**: ~30-40W #### Storage **OS/VM Storage:** | Pool | Devices | Type | Capacity | Purpose | |------|---------|------|----------|---------| | `nvme-mirror1` | 2x Sabrent Rocket Q NVMe | ZFS Mirror | 3.6 TB usable | High-performance VM storage | | `nvme-mirror2` | 2x Kingston SFYRD 2TB NVMe | ZFS Mirror | 1.8 TB usable | Additional fast VM storage | | `rpool` | 2x Samsung 870 QVO 4TB SSD | ZFS Mirror | 3.6 TB usable | Proxmox OS, containers, backups | **Total Storage**: ~9 TB usable #### GPUs | Model | Slot | VRAM | TDP | Purpose | Passed To | |-------|------|------|-----|---------|-----------| | NVIDIA Quadro P2000 | PCIe slot 1 | 5 GB GDDR5 | 75W | Plex transcoding | Host | | NVIDIA TITAN RTX | PCIe slot 2 | 24 GB GDDR6 | 280W | AI workloads | Saltbox (101), lmdev1 (111) | **Total GPU Power**: 75W + 280W = 355W (under load) #### Network Cards | Interface | Model | Speed | Purpose | Bridge | |-----------|-------|-------|---------|--------| | enp1s0 | Intel I210 (onboard) | 1 Gb | Management | vmbr0 | | enp35s0f0 | Intel X520 (dual-port SFP+) | 10 Gb | High-speed LXC | vmbr1 | | enp35s0f1 | Intel X520 (dual-port SFP+) | 10 Gb | High-speed VM | vmbr2 | **10Gb Transceivers**: Intel FTLX8571D3BCV (SFP+ 10GBASE-SR, 850nm, multimode) #### Storage Controllers | Model | Interface | Purpose | |-------|-----------|---------| | LSI SAS2308 HBA | PCIe 3.0 x8 | Passed to TrueNAS VM for EMC enclosure | | Samsung NVMe controller | PCIe | Passed to TrueNAS VM for ZFS caching | #### Motherboard - **Model**: Unknown - needs investigation - **Chipset**: AMD TRX40 - **Form Factor**: ATX/EATX - **PCIe Slots**: Multiple PCIe 4.0 slots - **Features**: IOMMU support, ECC memory #### Power Supply - **Model**: Unknown - **Wattage**: Likely 1000W+ (needs investigation) - **Type**: ATX, 80+ certification unknown #### Cooling - **CPU Cooler**: Unknown - likely large tower or AIO - **Case Fans**: Unknown quantity - **Note**: CPU temps 70-80°C under load (healthy) --- ### PVE2 (10.10.10.102) - Secondary Proxmox Server #### CPU - **Model**: AMD Ryzen Threadripper PRO 3975WX - **Specs**: Same as PVE (32C/64T, 280W TDP) #### RAM - **Capacity**: 128 GB DDR4 ECC - **Same specs as PVE** #### Storage | Pool | Devices | Type | Capacity | Purpose | |------|---------|------|----------|---------| | `nvme-mirror3` | 2x NVMe (model unknown) | ZFS Mirror | Unknown | High-performance VM storage | | `local-zfs2` | 2x WD Red 6TB HDD | ZFS Mirror | ~6 TB usable | Bulk/archival storage (spins down) | **HDD Spindown**: Configured for 30-min idle spindown (saves ~10-16W) #### GPUs | Model | Slot | VRAM | TDP | Purpose | Passed To | |-------|------|------|-----|---------|-----------| | NVIDIA RTX A6000 | PCIe slot 1 | 48 GB GDDR6 | 300W | AI trading workloads | trading-vm (301) | #### Network Cards | Interface | Model | Speed | Purpose | |-----------|-------|-------|---------| | nic1 | Unknown (onboard) | 1 Gb | Management | **Note**: MTU set to 9000 for jumbo frames #### Motherboard - **Model**: Unknown - **Chipset**: AMD TRX40 - **Similar to PVE** --- ## Network Equipment ### UniFi Dream Machine Pro (UCG-Fiber) - **Model**: UniFi Cloud Gateway Fiber - **IP**: 10.10.10.1 - **Ports**: Multiple 1Gb + SFP+ uplink - **Features**: Router, firewall, VPN, IDS/IPS - **MTU**: 9216 (supports jumbo frames) - **Tailscale**: Installed for VPN failover ### Switches **Details needed** - investigate current switch setup: - 10Gb switch for high-speed connections? - 1Gb switch for general devices? - PoE capabilities? ```bash # Check what's connected to 10Gb interfaces ssh pve 'ip link show enp35s0f0' ssh pve 'ip link show enp35s0f1' ``` --- ## Storage Hardware ### EMC Storage Enclosure **See [EMC-ENCLOSURE.md](EMC-ENCLOSURE.md) for complete details** - **Model**: EMC KTN-STL4 (or similar) - **Form Factor**: 4U rackmount - **Drive Bays**: 25x 3.5" SAS/SATA - **Controllers**: Dual LCC (Link Control Cards) - **Connection**: SAS via LSI SAS2308 HBA - **Passed to**: TrueNAS VM (VMID 100) **Current Status**: - LCC A: Active (working) - LCC B: Failed (replacement ordered) **Drive Inventory**: Unknown - needs audit ```bash # Get drive list from TrueNAS ssh truenas 'smartctl --scan' ssh truenas 'lsblk' ``` ### NVMe Drives | Model | Quantity | Capacity | Location | Pool | |-------|----------|----------|----------|------| | Sabrent Rocket Q | 2 | Unknown | PVE | nvme-mirror1 | | Kingston SFYRD | 2 | 2 TB each | PVE | nvme-mirror2 | | Unknown model | 2 | Unknown | PVE2 | nvme-mirror3 | | Samsung (model unknown) | 1 | Unknown | TrueNAS (passed) | ZFS cache | ### SSDs | Model | Quantity | Capacity | Location | Pool | |-------|----------|----------|----------|------| | Samsung 870 QVO | 2 | 4 TB each | PVE | rpool | ### HDDs | Model | Quantity | Capacity | Location | Pool | |-------|----------|----------|----------|------| | WD Red | 2 | 6 TB each | PVE2 | local-zfs2 | | Unknown (in EMC) | Unknown | Unknown | TrueNAS | vault | --- ## UPS ### Current UPS | Specification | Value | |---------------|-------| | **Model** | CyberPower OR2200PFCRT2U | | **Capacity** | 2200VA / 1320W | | **Form Factor** | 2U rackmount | | **Input** | NEMA 5-15P (rewired from 5-20P) | | **Outlets** | 2x 5-20R + 6x 5-15R | | **Output** | PFC Sinewave | | **Runtime** | ~15-20 min @ 33% load | | **Interface** | USB (connected to PVE) | **See [UPS.md](UPS.md) for configuration details** --- ## Client Devices ### Mac Mini (Hutson's Workstation) - **Model**: Unknown generation - **CPU**: Unknown - **RAM**: Unknown - **Storage**: Unknown - **Network**: 1Gb Ethernet (en0) - MTU 9000 - **Tailscale IP**: 100.108.89.58 - **Local IP**: 10.10.10.125 (static) - **Purpose**: Primary workstation, Happy Coder daemon host ### MacBook (Mobile) - **Model**: Unknown - **Network**: Wi-Fi + Ethernet adapter - **Tailscale IP**: Unknown - **Purpose**: Mobile work, development ### Windows PC - **Model**: Unknown - **CPU**: Unknown - **Network**: 1Gb Ethernet - **IP**: 10.10.10.150 - **Purpose**: Gaming, Windows development, Syncthing node ### Phone (Android) - **Model**: Unknown - **IP**: 10.10.10.54 (when on Wi-Fi) - **Purpose**: Syncthing mobile node, Happy Coder client --- ## Rack Layout (If Applicable) **Needs documentation** - Current rack configuration unknown Suggested format: ``` U42: Blank panel U41: UPS (CyberPower 2U) U40: UPS (CyberPower 2U) U39: Switch (10Gb) U38-U35: EMC Storage Enclosure (4U) U34: PVE Server U33: PVE2 Server ... ``` --- ## Power Consumption ### Measured Power Draw | Component | Idle | Typical | Peak | Notes | |-----------|------|---------|------|-------| | PVE Server | 250-350W | 500W | 750W | CPU + GPUs + storage | | PVE2 Server | 200-300W | 400W | 600W | CPU + GPU + storage | | Network Gear | ~50W | ~50W | ~50W | Router + switches | | **Total** | **500-700W** | **~950W** | **~1400W** | Exceeds UPS under peak load | **UPS Capacity**: 1320W **Typical Load**: 33-50% (safe margin) **Peak Load**: Can exceed UPS capacity temporarily (acceptable) ### Power Optimizations Applied **See [POWER-MANAGEMENT.md](POWER-MANAGEMENT.md) for details** - KSMD disabled: ~60-80W saved - CPU governors: ~60-120W saved - Syncthing rescans: ~60-80W saved - HDD spindown: ~10-16W saved when idle - **Total savings**: ~150-300W --- ## Thermal Management ### CPU Cooling **PVE & PVE2**: - CPU cooler: Unknown model - Thermal paste: Unknown, likely needs refresh if temps >85°C - Target temp: 70-80°C under load - Max safe: 90°C Tctl (Threadripper PRO spec) ### GPU Cooling All GPUs are passively managed (stock coolers): - TITAN RTX: 2-3W idle, 280W load - RTX A6000: 11W idle, 300W load - Quadro P2000: 25W constant (Plex active) ### Case Airflow **Unknown** - needs investigation: - Case model? - Fan configuration? - Positive or negative pressure? --- ## Cable Management ### Network Cables | Connection | Type | Length | Speed | |------------|------|--------|-------| | PVE → Switch (10Gb) | OM3 fiber | Unknown | 10Gb | | PVE2 → Router | Cat6 | Unknown | 1Gb | | Mac Mini → Switch | Cat6 | Unknown | 1Gb | | TrueNAS → EMC | SAS cable | Unknown | 6Gb/s | ### Power Cables **Critical**: All servers on UPS battery-backed outlets --- ## Maintenance Schedule ### Annual Maintenance - [ ] Clean dust from servers (every 6-12 months) - [ ] Check thermal paste on CPUs (every 2-3 years) - [ ] Test UPS battery runtime (annually) - [ ] Verify all fans operational - [ ] Check for bulging capacitors on PSUs ### Drive Health ```bash # Check SMART status on all drives ssh pve 'smartctl -a /dev/nvme0' ssh pve2 'smartctl -a /dev/sda' ssh truenas 'smartctl --scan | while read dev type; do echo "=== $dev ==="; smartctl -a $dev | grep -E "Model|Serial|Health|Reallocated|Current_Pending"; done' ``` ### Temperature Monitoring ```bash # Check all temps (needs lm-sensors installed) ssh pve 'sensors' ssh pve2 'sensors' ``` --- ## Warranty & Purchase Info **Needs documentation**: - When were servers purchased? - Where were components bought? - Any warranties still active? - Replacement part sources? --- ## Upgrade Path ### Short-term Upgrades (< 6 months) - [ ] 20A circuit for UPS (restore original 5-20P plug) - [ ] Document missing hardware specs - [ ] Label all cables - [ ] Create rack diagram ### Medium-term Upgrades (6-12 months) - [ ] Additional 10Gb NIC for PVE2? - [ ] More NVMe storage? - [ ] Upgrade network switches? - [ ] Replace EMC enclosure with newer model? ### Long-term Upgrades (1-2 years) - [ ] CPU upgrade to newer Threadripper? - [ ] RAM expansion to 256GB? - [ ] Additional GPU for AI workloads? - [ ] Migrate to PCIe 5.0 storage? --- ## Investigation Needed High-priority items to document: - [ ] Get exact motherboard model (both servers) - [ ] Get PSU model and wattage - [ ] CPU cooler models - [ ] Network switch models and configuration - [ ] Complete drive inventory in EMC enclosure - [ ] RAM speed and timings - [ ] Case models - [ ] Exact NVMe models for all drives **Commands to gather info**: ```bash # Motherboard ssh pve 'dmidecode -t baseboard' # CPU details ssh pve 'lscpu' # RAM details ssh pve 'dmidecode -t memory | grep -E "Size|Speed|Manufacturer"' # Storage devices ssh pve 'lsblk -o NAME,SIZE,TYPE,TRAN,MODEL' # Network cards ssh pve 'lspci | grep -i network' # GPU details ssh pve 'lspci | grep -i vga' ssh pve 'nvidia-smi -L' # If nvidia-smi available ``` --- ## Related Documentation - [VMS.md](VMS.md) - VM resource allocation - [STORAGE.md](STORAGE.md) - Storage pools and usage - [POWER-MANAGEMENT.md](POWER-MANAGEMENT.md) - Power optimizations - [UPS.md](UPS.md) - UPS configuration - [NETWORK.md](NETWORK.md) - Network configuration - [EMC-ENCLOSURE.md](EMC-ENCLOSURE.md) - Storage enclosure details --- **Last Updated**: 2025-12-22 **Status**: ⚠️ Incomplete - many specs need investigation